{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it,pl","rcn":"83835","id":"83835-realtime-detection-and-analysis-of-microemboli","title":"Real-time detection and analysis of micro-emboli","teaser":"The UMEDS project work has resulted in an automated embolus detection system that allows inexpensive on-line analysis of detected micro-embolic signals (MESs).","body":"\u003Csection\u003E\u003CsectionBody\u003EStroke is considered as one of the most rapidly increasing diseases in the Western World that, due to its complexity, may be difficult to diagnose. Urged by this, the UMEDS project focused on a new non-invasive means for improved monitoring and early diagnosis of stroke. Taking advantage of recent advancements in microbubble technology and ultrasonographic harmonic imaging, novel ultrasound techniques for both qualitative and quantitative evaluation of brain perfusion were developed.\n\nKey innovations included advanced ultrasound technology, new approaches to brain perfusion imaging, and novel microbubble technology for molecular imaging and thrombolysis. One of the key technologies that were developed was an automated system for detection of micro-emboli. Conventional methods for detection of microemboli in the cerebral circulation are based on transcranial Doppler (TCD) ultrasound information. The derived information undergoes further processing for detection and analysis of MESs, which is a costly, time-consuming and resourceful procedure.\n\nTo fulfil this need, the UMEDS designed a knowledge-based system for automated identification and archival of MESs in real-time. It includes a PC and a powerful digital signal processing (DSP) board that provides Fast Fourier Transform (FFT) spectral analysis and MES detection. Information extracts from the input Doppler signals concerning time, frequency and neighbourhood domains are further processed with the aid of expert system reasoning theory. Archiving includes data files with each detected event, the respective segments of the raw Doppler signal and all relevant information.\n\nThe technology has already been tested using Doppler signals derived from carotid endarterectomy patients and healthy volunteers. It was found extremely sensitive and highly specific in the detection and analysis of micro-emboli.\u003C\/sectionBody\u003E\u003C\/section\u003E","contentCreationDate":"2008-03-03 14:23:56","contentUpdateDate":"2008-03-03 14:23:56","lastUpdateDate":"2019-09-13 10:00:11","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"health","title":"Health","displayCode":"\/Health","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"400720","id":"400720-results-supplement-no-004","title":"Results Supplement No. 004","contentUpdateDate":"2008-05-01 00:00:01","archivedDate":"2024-05-29 00:00:00","relations":{"categories":[{"language":"en","code":"mag","title":"research*eu magazine","description":"Article: Both results and focus magazines","displayCode":"\/research*eu magazine","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/article\/images\/2017-10\/400720.jpg","mimetype":"image\/jpeg","size":"0","contenttype":"webItem","attributes":{"represents":"magazineCover","source":"editorial","type":"relatedImage"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","title":"Download ePUB version","id":"3c6d05a2-9a63-4e74-a9f7-726ec29dc125_epub","physUrl":"https:\/\/op.europa.eu\/o\/opportal-service\/download-handler?identifier=3c6d05a2-9a63-4e74-a9f7-726ec29dc125\u0026format=EPUB\u0026language=en\u0026productionSystem=cellar","status":"legacy","contenttype":"webLink","attributes":{"represents":"article","source":"editorial","type":"formatEpub"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","title":"Download PDF version","id":"3c6d05a2-9a63-4e74-a9f7-726ec29dc125_pdf","physUrl":"https:\/\/op.europa.eu\/o\/opportal-service\/download-handler?identifier=3c6d05a2-9a63-4e74-a9f7-726ec29dc125\u0026format=PDF\u0026language=en\u0026productionSystem=cellar","status":"legacy","contenttype":"webLink","attributes":{"represents":"article","source":"editorial","type":"formatPdf"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","defaultLanguage":"en","title":"Order paper copy","id":"3c6d05a2-9a63-4e74-a9f7-726ec29dc125_print","physUrl":"https:\/\/op.europa.eu\/en\/publication-detail\/-\/publication\/3c6d05a2-9a63-4e74-a9f7-726ec29dc125\/","status":"legacy","contenttype":"webLink","attributes":{"represents":"article","source":"editorial","type":"orderPrint"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"isContainedIn"}},{"availableLanguages":"en","rcn":"64847","id":"QLG1-CT-2002-01518","acronym":"UMEDS","teaser":"The UMEDS project will establish non-invasive techniques for early diagnosis and bedside monitoring of stroke to improve stroke outcome. An important goal will be to expand recent developments in microbubble technology and ultrasonographic harmonic imaging to establish ultraso...","title":"Ultrasonographic monitoring and early diagnosis of stroke","archivedDate":"2024-05-24 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/73\/453\/457","title":"control systems","displayCode":"\/engineering and technology\/electrical engineering, electronic engineering, information engineering\/electronic engineering\/control systems","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/35\/153\/635","title":"stroke","displayCode":"\/medical and health sciences\/basic medicine\/neurology\/stroke","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/43\/273\/813","title":"ultrasound","displayCode":"\/natural sciences\/physical sciences\/acoustics\/ultrasound","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it","rcn":"640","code":"FP5-LIFE QUALITY","frameworkProgramme":"FP5","pga":"FP5-LIFE QUALITY","title":"Specific Programme for research, technological development and demonstration on \u0022Quality of life and management of living resources\u0022, 1998-2002","shortTitle":"Quality of life and management of living resources","parent":{"rcn":"624","code":"FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"4984","code":"1.1.1.-7.","frameworkProgramme":"FP5","title":"Chronic and degenerative diseases, cancer, diabetes, cardivascular diseases and rare diseases","parent":{"rcn":"4956\/640\/624","code":"1.1.1.\/FP5-LIFE QUALITY\/FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"availableLanguages":"en","rcn":"40334","title":"Automatic embolus detection system","teaser":"Identification of microemboli in the cerebral circulation using transcranial Doppler (TCD) ultrasound provides valuable clinical information, but currently micro-embolic signal (MES) detection and analysis are significantly limited as they rely mainly on costly off-line manual...","contentUpdateDate":"2006-07-03 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"id14","title":"Prototype\/demonstrator available for testing","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"rcn":"64847","id":"QLG1-CT-2002-01518","title":"Ultrasonographic monitoring and early diagnosis of stroke","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/73\/453\/457","title":"control systems","displayCode":"\/engineering and technology\/electrical engineering, electronic engineering, information engineering\/electronic engineering\/control systems","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/35\/153\/635","title":"stroke","displayCode":"\/medical and health sciences\/basic medicine\/neurology\/stroke","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/43\/273\/813","title":"ultrasound","displayCode":"\/natural sciences\/physical sciences\/acoustics\/ultrasound","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"eTip","type":"relatedProject"}}]},"contenttype":"result","attributes":{"source":"editorial","type":"relatedResult"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2008-03\/40334.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Shutterstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}],"regions":[{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"source":"editorial","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}