{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it,pl","rcn":"84113","id":"84113-fits-like-a-glove","title":"Fits like a glove","teaser":"Scientists based at the University of Salford have designed a new hand haptic device made up of resistance and electromagnetic sensors. This study contributes to the advancement of the biomedical profession and has the potential to improve understanding of physiological and pathological conditions.","body":"\u003Csection\u003E\u003CsectionBody\u003EThe research is part of a larger project works on the basis of furthering scientific understanding of the functionality of the human anatomy and physiological and pathological conditions associated with it. Such research undertaken by the MULTISENSE project, it is hoped, will speed up the progress being made in the medical field and industrial areas such as biomedical engineering. In particular the focus has been to find a way to represent the functional anatomy in a 3D way, which up until now has proved very difficult. Creating such 3D representations will enable the visual and virtual manipulation of these anatomical objects and so enable innovative techniques to be tested.\n\nScientists at the University of Salford in the UK have turned their attention to the creation of a hand exoskeleton structure. It can be used both to simulate the hand and to support it as it strengthens the overall movements, grasping and flexing. The device operates on the index, middle and ring fingers and the thumb, providing a feedback force from the dorsal side of the hand. The feedback forces are generated by direct current motors mounted in a low profile power pack and are transmitted to the fingers by low friction pull-cables. The device allows for the measurement of the finger flexion, which is possible due to the combination of flexible resistive sensors and electromagnetic sensors embedded in the glove.\n\nThe device is made out of soft lycra glove and a metallic structure; this enables ease of movement and allows for the measurements to be taken. The incorporated glove, unlike other systems, is part of the exoskeleton structure and thus it is faster to put on and take off. It is designed to fit a range of hand sizes and for this purpose it incorporates adjustment levers that allow fast and easy adjustment of the metallic structure for the three fingers.\u003C\/sectionBody\u003E\u003C\/section\u003E","contentCreationDate":"2008-06-05 13:50:07","contentUpdateDate":"2008-06-05 13:50:07","lastUpdateDate":"2019-09-12 22:02:04","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ict","title":"Digital Economy","displayCode":"\/Digital Economy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"400710","id":"400710-results-supplement-no-008","title":"Results Supplement No. 008","contentUpdateDate":"2008-10-01 00:00:01","archivedDate":"2024-05-29 00:00:00","relations":{"categories":[{"language":"en","code":"mag","title":"research*eu magazine","description":"Article: Both results and focus magazines","displayCode":"\/research*eu magazine","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/article\/images\/2017-10\/400710.jpg","mimetype":"image\/jpeg","size":"7717","contenttype":"webItem","attributes":{"represents":"magazineCover","source":"editorial","type":"relatedImage"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","title":"Download ePUB version","id":"f7e7cef8-c117-4a0e-b441-4107ffb78fa1_epub","physUrl":"https:\/\/op.europa.eu\/o\/opportal-service\/download-handler?identifier=f7e7cef8-c117-4a0e-b441-4107ffb78fa1\u0026format=EPUB\u0026language=en\u0026productionSystem=cellar","status":"legacy","contenttype":"webLink","attributes":{"represents":"article","source":"editorial","type":"formatEpub"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","title":"Download PDF version","id":"f7e7cef8-c117-4a0e-b441-4107ffb78fa1_pdf","physUrl":"https:\/\/op.europa.eu\/o\/opportal-service\/download-handler?identifier=f7e7cef8-c117-4a0e-b441-4107ffb78fa1\u0026format=PDF\u0026language=en\u0026productionSystem=cellar","status":"legacy","contenttype":"webLink","attributes":{"represents":"article","source":"editorial","type":"formatPdf"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","defaultLanguage":"en","title":"Order paper copy","id":"f7e7cef8-c117-4a0e-b441-4107ffb78fa1_print","physUrl":"https:\/\/op.europa.eu\/en\/publication-detail\/-\/publication\/f7e7cef8-c117-4a0e-b441-4107ffb78fa1\/","status":"legacy","contenttype":"webLink","attributes":{"represents":"article","source":"editorial","type":"orderPrint"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"isContainedIn"}},{"availableLanguages":"en","rcn":"63281","id":"IST-2001-34121","acronym":"MULTISENSE","teaser":"Accurate knowledge of human functional anatomy, in physiological and pathological conditions, is of importance in many medical fields, as in industrial areas such as biomedical engineering. The 3D aspects of functional anatomy are particularly important but they are exceedingl...","title":"MULTImodal and multiSENSory interfaces for intEraction with muscolo-skeletal Models","archivedDate":"2024-05-27 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/37","title":"medical biotechnology","displayCode":"\/medical and health sciences\/medical biotechnology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/47\/307","title":"software","displayCode":"\/natural sciences\/computer and information sciences\/software","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/35\/151","title":"anatomy and morphology","displayCode":"\/medical and health sciences\/basic medicine\/anatomy and morphology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/35\/145","title":"pathology","displayCode":"\/medical and health sciences\/basic medicine\/pathology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/57\/693","title":"diagnostic imaging","displayCode":"\/engineering and technology\/medical engineering\/diagnostic imaging","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it","rcn":"641","code":"FP5-IST","frameworkProgramme":"FP5","pga":"FP5-IST","title":"Programme for research, technological development and demonstration on a \u0022User-friendly information society, 1998-2002\u0022","shortTitle":"User-friendly information society","parent":{"rcn":"624","code":"FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"6673","code":"2001-5.1.2","frameworkProgramme":"FP5","title":"CPA2: Multimodal and multisensorial dialogue modes","parent":{"rcn":"6671\/641\/624","code":"2001-5\/FP5-IST\/FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"availableLanguages":"en","rcn":"43132","title":"Low mass hand haptic device","teaser":"The hand exoskeleton device is a system that was developed to provides force feedback to the index, middle and ring fingers and to the thumb. \n\nFor the first three fingers force feedback is provided for their proximal and distal phalanxes while for the thumb only the distal ph...","contentUpdateDate":"2006-11-28 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"id14","title":"Prototype\/demonstrator available for testing","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"rcn":"63281","id":"IST-2001-34121","title":"MULTImodal and multiSENSory interfaces for intEraction with muscolo-skeletal Models","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/37","title":"medical biotechnology","displayCode":"\/medical and health sciences\/medical biotechnology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/47\/307","title":"software","displayCode":"\/natural sciences\/computer and information sciences\/software","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/35\/151","title":"anatomy and morphology","displayCode":"\/medical and health sciences\/basic medicine\/anatomy and morphology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/35\/145","title":"pathology","displayCode":"\/medical and health sciences\/basic medicine\/pathology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/57\/693","title":"diagnostic imaging","displayCode":"\/engineering and technology\/medical engineering\/diagnostic imaging","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"eTip","type":"relatedProject"}}]},"contenttype":"result","attributes":{"source":"editorial","type":"relatedResult"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2008-06\/43132.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Shutterstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}],"regions":[{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"source":"editorial","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}