{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it,pl","rcn":"84783","id":"84783-predicting-osseointegration-of-dental-implants","title":"Predicting osseo-integration of dental implants","teaser":"Researchers developed computer models to help create one-stage placements for dental implants. The methodologies developed were combined with results from guinea pig and human studies to predict integration between the living bone and the implant.","body":"\u003Csection\u003E\u003CsectionBody\u003EProblems arising from the permucosal fixation of oral prostheses are associated with an ageing population, such as in Europe. Standard dental practice has been to fit the prosthesis onto a supporting implant. This follows a period where the area surrounding the unloaded implant has been allowed to heal. However, one-stage placements of implants, which can accept immediate loading, have been developed. These have improved patients\u0027 quality of life by enabling an earlier return to normality.\n\nThe IMLOAD project studied the reaction of bone to the effects of controlled mechanical loading and the fixation of a dental implant. Models of the dental implant-bone complex were developed by the team. The aim of the models was to help improve the design of dental implants, facilitating the long-term connection between living bone and the surface of a load-bearing artificial implant. This process is known as known as osseo-integration. The extent of bone growth and resorption was predicted with a bone remodelling algorithm. Further research was planned to more successfully integrate the algorithm into a commercial finite element framework.\n\nResearchers developed a methodology for producing 3D models of cancellous and cortical bone, bone marrow and artificial dental implants. Cancellous material has low density and strength but a large surface area, whereas cortical or compact bone material is dense and forms the surface of bone. A methodology was also developed for creating models for the analysis of artificial biomaterials and biological tissues and structures.\n\nThe team used these methodologies to build finite element models of guinea pigs and patients used in pilot studies. The algorithm used for bone remodelling was applied to the guinea pig results. The methodologies developed were then combined in order to predict osseo-integration in human patients.\n\nFigure caption: Stress distribution in mandibular bone.\u003C\/sectionBody\u003E\u003C\/section\u003E","contentCreationDate":"2009-02-09 17:37:47","contentUpdateDate":"2009-02-09 17:37:47","lastUpdateDate":"2019-09-13 11:56:45","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"health","title":"Health","displayCode":"\/Health","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"400744","id":"400744-results-supplement-no-015","title":"Results Supplement No. 015","contentUpdateDate":"2009-06-01 00:00:01","archivedDate":"2024-05-29 00:00:00","relations":{"categories":[{"language":"en","code":"mag","title":"research*eu magazine","description":"Article: Both results and focus magazines","displayCode":"\/research*eu magazine","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/article\/images\/2017-10\/400744.jpg","mimetype":"image\/jpeg","size":"0","contenttype":"webItem","attributes":{"represents":"magazineCover","source":"editorial","type":"relatedImage"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","title":"Download ePUB version","id":"ab5058c1-e8af-41c6-a141-b0916495da11_epub","physUrl":"https:\/\/op.europa.eu\/o\/opportal-service\/download-handler?identifier=ab5058c1-e8af-41c6-a141-b0916495da11\u0026format=EPUB\u0026language=en\u0026productionSystem=cellar","status":"legacy","contenttype":"webLink","attributes":{"represents":"article","source":"editorial","type":"formatEpub"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","title":"Download PDF version","id":"ab5058c1-e8af-41c6-a141-b0916495da11_pdf","physUrl":"https:\/\/op.europa.eu\/o\/opportal-service\/download-handler?identifier=ab5058c1-e8af-41c6-a141-b0916495da11\u0026format=PDF\u0026language=en\u0026productionSystem=cellar","status":"legacy","contenttype":"webLink","attributes":{"represents":"article","source":"editorial","type":"formatPdf"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","defaultLanguage":"en","title":"Order paper copy","id":"ab5058c1-e8af-41c6-a141-b0916495da11_print","physUrl":"https:\/\/op.europa.eu\/en\/publication-detail\/-\/publication\/ab5058c1-e8af-41c6-a141-b0916495da11\/","status":"legacy","contenttype":"webLink","attributes":{"represents":"article","source":"editorial","type":"orderPrint"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"isContainedIn"}},{"availableLanguages":"en","rcn":"67195","id":"QLK6-CT-2002-02442","acronym":"IMLOAD","teaser":"Problems associated with perrnucosal fixation of oral prostheses, using osseointegrated implants, are mainly found in the ageing population. Standard practice is to fit prostheses onto supporting implants after a period of unloaded healing. One-stage placement of implants and ...","title":"Improving implant fixation by immediate loading","archivedDate":"2024-05-24 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/39\/227","title":"physiotherapy","displayCode":"\/medical and health sciences\/clinical medicine\/physiotherapy","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/37\/677","title":"implants","displayCode":"\/medical and health sciences\/medical biotechnology\/implants","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it","rcn":"640","code":"FP5-LIFE QUALITY","frameworkProgramme":"FP5","pga":"FP5-LIFE QUALITY","title":"Specific Programme for research, technological development and demonstration on \u0022Quality of life and management of living resources\u0022, 1998-2002","shortTitle":"Quality of life and management of living resources","parent":{"rcn":"624","code":"FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"4978","code":"1.1.1.-6.","frameworkProgramme":"FP5","title":"Key action The Ageing Population and Disabilities","parent":{"rcn":"4956\/640\/624","code":"1.1.1.\/FP5-LIFE QUALITY\/FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"availableLanguages":"en","rcn":"44681","title":"Computational environment to predict in-vivo osseo-integration in human subjects","teaser":"UWCM contributed to the 3D modelling effort in the project:\n\n1. Parametric modelling of implant designs \nParametric finite element models of dental implant-bone complex were developed combining non-linear contact analyses and optimisation numerical routines aimed at optimising...","contentUpdateDate":"2007-12-12 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"id27","title":"Software code","displayCode":"\/Software code","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"rcn":"67195","id":"QLK6-CT-2002-02442","title":"Improving implant fixation by immediate loading","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/39\/227","title":"physiotherapy","displayCode":"\/medical and health sciences\/clinical medicine\/physiotherapy","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/37\/677","title":"implants","displayCode":"\/medical and health sciences\/medical biotechnology\/implants","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"eTip","type":"relatedProject"}}]},"contenttype":"result","attributes":{"source":"editorial","type":"relatedResult"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/images\/2009-02\/44681.jpg","mimetype":"image\/jpeg","size":"0","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}],"regions":[{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"source":"editorial","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}