{"contenttype":"project","language":"en","availableLanguages":"en","rcn":"67942","id":"EVK1-CT-2002-00122","acronym":"CADOX","teaser":"The IPPC Directive has request the development of technologies for the minimisation of pollution \u0026 for the development of water recycling. Due to the lack of available on-site technologies, a large quantity of the industrial activities included in Annex I of IPPC Direct. are n...","objective":"The IPPC Directive has request the development of technologies for the minimisation of pollution \u0026 for the development of water recycling. Due to the lack of available on-site technologies, a large quantity of the industrial activities included in Annex I of IPPC Direct. are not treating these wastewaters appropriately. This Proposal address to the optimisation of a hybrid technology combining solar photocatalysis, ozone and bioprocesses to the treatment of wastewaters containing Priority Hazardous Substances for permitting the reuse of this water. CADOX proposal will focus on non-biodegradable chlorinated solvents and pesticides. The expected result would be a new technology (CADOX) with market possibilities and suitable to be applied for the remediation of wastewaters with organic contaminants. This technology would be assessed by the set-up, testing and optimisation of a demonstration plant during the last step of the project.\n\n","title":"A coupled advanced oxidation-biological process for recycling of industrial waste waters containing persistent organic contaminants","totalCost":"3003884","ecMaxContribution":"1217913","startDate":"2003-02-01","endDate":"2006-07-31","validation":{"euroSciVoc":"false"},"contentCreationDate":"2003-02-10 00:00:00","contentUpdateDate":"2005-07-28 00:00:00","lastUpdateDate":"2026-02-18 16:58:16","archivedDate":"2024-05-21 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"84378","id":"84378-ozone-and-biotreatment-technology-for-wastewater","title":"Ozone and biotreatment technology for wastewater","teaser":"Hybrid technology used ozone and bioprocesses to treat wastewaters containing Priority Hazardous Substances (PHS). The system significantly reduced the cost of treating wastewater, which could then be reused in agriculture, industry or for recharging the water table.","contentUpdateDate":"2008-09-08 14:23:18","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"env","title":"Climate Change and Environment","displayCode":"\/Climate Change and Environment","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"400713","title":"Results Supplement No. 009","archivedDate":"2024-05-29 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"mag","title":"research*eu magazine","description":"Article: Both results and focus magazines","displayCode":"\/research*eu magazine","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"isContainedIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2008-09\/43905.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Shutterstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"84397","id":"84397-ecological-approach-to-seawater-decontamination","title":"Ecological approach to seawater decontamination","teaser":"An innovative, effective method of cleaning up polluted seawater has been discovered by DSM Deretil SA and its partners in the CADOX RTD project.","contentUpdateDate":"2008-09-15 14:23:25","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"env","title":"Climate Change and Environment","displayCode":"\/Climate Change and Environment","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"400710","title":"Results Supplement No. 008","archivedDate":"2024-05-29 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"mag","title":"research*eu magazine","description":"Article: Both results and focus magazines","displayCode":"\/research*eu magazine","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"isContainedIn"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/images\/2008-09\/43935.jpg","mimetype":"image\/jpeg","size":"0","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"84357","id":"84357-treatment-of-wastewater-by-tio2-and-photofenton","title":"Treatment of wastewater by TiO2 and photo-Fenton","teaser":"EU legislation in the form of the IPPC Directive (96\/61\/EC) precipitated the development of technologies for water recycling and pollution control for specific industrial sectors. The photo-Fenton and titanium dioxide wastewater treatment systems were assessed for their suitability in treating water containing chlorinated solvents.","contentUpdateDate":"2008-09-01 17:39:51","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"env","title":"Climate Change and Environment","displayCode":"\/Climate Change and Environment","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"400713","title":"Results Supplement No. 009","archivedDate":"2024-05-29 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"mag","title":"research*eu magazine","description":"Article: Both results and focus magazines","displayCode":"\/research*eu magazine","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"isContainedIn"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/images\/2008-09\/43906.jpg","mimetype":"image\/jpeg","size":"0","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"85002","id":"85002-hybrid-technology-for-the-decontamination-of-industrial-wastewaters","title":"Hybrid technology for the decontamination of industrial wastewaters","teaser":"Aiming to address the inability of conventional wastewater treatments to effectively remove major toxic contaminants, the CADOX project has coupled chemical with biological oxidation processes. Their use as a pre-treatment step in an integrated treatment system has been proposed as a cost-effective solution to enhance the biodegradability of industrial wastewaters.","contentUpdateDate":"2009-06-22 14:23:58","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"env","title":"Climate Change and Environment","displayCode":"\/Climate Change and Environment","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"400742","title":"Results Supplement No. 016","archivedDate":"2024-05-29 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"mag","title":"research*eu magazine","description":"Article: Both results and focus magazines","displayCode":"\/research*eu magazine","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"isContainedIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2009-06\/43904.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Shutterstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"en","rcn":"344551","legalName":"CENTRO DE INVESTIGACIONES ENERGETICAS, MEDIAMBIENTALES Y TECNOLOGICAS","address":{"street":"S\/N,Carretera Senes S\/N","city":"TABERNAS","postalCode":"04200","country":"ES"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"coordinator","order":"1"}},{"availableLanguages":"en","rcn":"350002","legalName":"NATIONAL LABORATORY FOR ENGINEERING AND INDUSTRIAL TECHNOLOGY","address":{"street":"Estrada do Paco do Lumiar 22, Edificio G","city":"LISBOA","postalCode":"1649-038","country":"PT"},"relations":{"regions":[{"name":"Portugal","rcn":"427199016","nutsCode":"PT","euCode":"PT","isoCode":"PT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"7"}},{"availableLanguages":"en","rcn":"353209","legalName":"TRAILIGAZ CIE GENERALE DE L\u0027OZONE SA","address":{"street":"Boulevard de la Muette 29-31","city":"GARGES-LES-GONESSE","postalCode":"95140","country":"FR"},"relations":{"regions":[{"name":"France","rcn":"258902568","nutsCode":"FR","euCode":"FR","isoCode":"FR","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"9"}},{"availableLanguages":"en","rcn":"353626","legalName":"AUTONOMOUS UNIVERSITY OF BARCELONA","address":{"street":"Campus Universitario, Edificio C","city":"BELLATERRA","postalCode":"08193","country":"ES"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"3"}},{"availableLanguages":"en","rcn":"529940","legalName":"ECOSYSTEM ENVIRONMENTAL SERVICES SA","address":{"street":"76,Travessia Turo d\u0027en Llull, 12","city":"LLAVANERES","postalCode":"08392","country":"ES","url":"http:\/\/www.solardetox.net\/"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"5"}},{"availableLanguages":"en","rcn":"887895","legalName":"AOSOL - ENERGIAS RENOVAVEIS, LDA.","address":{"street":"Parque Industrial de Porto Alto, Lugar de Sesmaria","city":"SAMORA CORREIA","postalCode":"2135","country":"PT"},"relations":{"regions":[{"name":"Portugal","rcn":"427199016","nutsCode":"PT","euCode":"PT","isoCode":"PT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"2"}},{"availableLanguages":"en","rcn":"946241","legalName":"SWISS FEDERAL INSTITUTE OF TECHNOLOGY LAUSANNE","address":{"street":"EPFL - Ecublens","city":"LAUSANNE","postalCode":"1015","country":"CH"},"relations":{"regions":[{"name":"Switzerland","rcn":"205949480","nutsCode":"CH","euCode":"CH","isoCode":"CH","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"8"}},{"availableLanguages":"en","rcn":"985853","legalName":"JANSSEN PHARMACEUTICA N.V.","address":{"street":"Turnhoutseweg 30","city":"BEERSE","postalCode":"2340","country":"BE"},"relations":{"regions":[{"name":"Belgium","rcn":"188385832","nutsCode":"BE","euCode":"BE","isoCode":"BE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"6"}},{"availableLanguages":"en","rcn":"985855","legalName":"DSM DERETIL SA","address":{"street":"Villaricos","city":"CUEVAS DEL ALMANZORA","postalCode":"04618","country":"ES"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"4"}},{"availableLanguages":"de,en,es,fr,it","rcn":"643","id":"FP5-EESD","code":"FP5-EESD","frameworkProgramme":"FP5","pga":"FP5-EESD","title":"Programme for research, technological development and demonstration on \u0022Energy, environment and sustainable development, 1998-2002\u0022","shortTitle":"Energy, environment and sustainable development","parent":{"rcn":"624","code":"FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"6041","id":"FP5-EESD_1.1.4.-1.","code":"1.1.4.-1.","frameworkProgramme":"FP5","title":"Key action Sustainable Management and Quality of Water","parent":{"rcn":"643\/624","code":"FP5-EESD\/FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}},{"availableLanguages":"en","rcn":"43906","id":"EVK1-CT-2002-00122_43906_DELIV","title":"Treatment of wastewater containing chlorinated solvents by solar photocatalysis and photo-Fenton","teaser":"Article 16 of the European Union Water Framework Directive (2000\/60\/EC) set out a \u0022Strategy against pollution of water\u0022. The first stage in the strategy was a list of priority substances which would become Annex X of the Directive. Once the list of priority substances has been...","sourceUpdateDate":"2017-02-15 12:23:02","contentUpdateDate":"2007-04-20 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"84357","title":"Treatment of wastewater by TiO2 and photo-Fenton","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"env","title":"Climate Change and Environment","displayCode":"\/Climate Change and Environment","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"en","rcn":"3131998","legalName":"PLATAFORMA SOLAR DE ALMERIA-CIEMAT","address":{"street":"carretera Sen\u00e9s km 4, Tabernas","city":"ALMERIA","postalCode":"04200","country":"ES"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id14","title":"Prototype\/demonstrator available for testing","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"43907","id":"EVK1-CT-2002-00122_43907_DELIV","title":"Combination of ozone and photo-fenton for treatment of wastewater containing pesticides","teaser":"The coupling between Photo-Fenton and ozonation has been used as Advanced Oxidation Proces for the degradation of the following biorecalcitrant pesticides: alachlor, atrazine, chlorfenvinfos, diuron, isoproturon and pentachlorophenol.These organic compounds are considered Prio...","sourceUpdateDate":"2017-02-15 12:23:02","contentUpdateDate":"2007-04-20 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id17","title":"Scientific and\/or technical knowledge (basic research)","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3132003","legalName":"AUTONOMOUS UNIVERSITY OF BARCELONA","address":{"street":"Campus Universitario, Departament de Qu\u00edmica.","city":"BELLATERRA","postalCode":"08193","country":"ES"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"43904","id":"EVK1-CT-2002-00122_43904_DELIV","title":"Coupling between ozone and biotreatment for decontamination of wastewater containing pesticides","teaser":"The experimental conditions that lead to an optimisation of the ozone treatment of effluents containing recalcitrant organic substances such as the CADOX target compounds, i.e., alachlor, atrazine, chlorfenvinfos, diuron, isoproturon and pentachlorophenol,have been obtained. P...","sourceUpdateDate":"2017-02-15 12:23:01","contentUpdateDate":"2007-04-20 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"85002","title":"Hybrid technology for the decontamination of industrial wastewaters","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"env","title":"Climate Change and Environment","displayCode":"\/Climate Change and Environment","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"en","rcn":"3131988","legalName":"AUTONOMOUS UNIVERSITY OF BARCELONA","address":{"street":"Campus Universitario, Departament de Qu\u00edmica.","city":"BELLATERRA","postalCode":"08193","country":"ES"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id13","title":"Experimental development stage (laboratory prototype)","displayCode":"\/Experimental development stage (laboratory prototype)","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"43935","id":"EVK1-CT-2002-00122_43935_DELIV","title":"Treatment of biorecalcitrant compounds in saline wastewater by photo-Fenton","teaser":"A coupled solar photocatalytic-biological system has been developed to enhance the biodegradability and complete mineralization of a biorecalcitrant industrial compound, methylphenylglycine, dissolved in seawater at 500 mg L-1. The pollutant was completely degraded by a solar ...","sourceUpdateDate":"2017-02-15 12:23:15","contentUpdateDate":"2007-04-20 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"84397","title":"Ecological approach to seawater decontamination","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"env","title":"Climate Change and Environment","displayCode":"\/Climate Change and Environment","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"en","rcn":"3132129","legalName":"DSM DERETIL SA","address":{"street":"Villaricos","city":"CUEVAS DEL ALMANZORA","postalCode":"04618","country":"ES"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id15","title":"Results of demonstration trials available","displayCode":"\/Results of demonstration trials available","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"43908","id":"EVK1-CT-2002-00122_43908_DELIV","title":"Construction of solar photocatalytic wastewater treatment plants","teaser":"SolarCadox is based on the Photo-FENTON process, a combination of a well-known reaction discovered in 1894 with the most recent advances of photochemistry. The Fenton reagent is the iron II-salt-dependent decomposition of hydrogen peroxide generating the highly reactive hydrox...","sourceUpdateDate":"2017-02-15 12:23:03","contentUpdateDate":"2007-04-20 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id15","title":"Results of demonstration trials available","displayCode":"\/Results of demonstration trials available","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3132005","legalName":"ECOSYSTEM ENVIRONMENTAL SERVICES SA","address":{"street":"Travesia Turo d\u0027en Llull, 12","city":"SANT ANDREU DE LLAVANERES","postalCode":"08392","country":"ES","url":"http:\/\/www.solardetox.net"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"43903","id":"EVK1-CT-2002-00122_43903_DELIV","title":"Design and detailed engineering of biological wastewater treatment plant coupled with Advanced Oxidation Treatment","teaser":"Photo-Fenton treatment with 20 mg L-1 of Fe2+ was efficient enough, and no catalyst separation was required in the combined system AOP-biotreatment, as the concentration was low enough to ensure non-inhibitory effects on the activated sludge. \n\nEvaluation of the combined photo...","sourceUpdateDate":"2017-02-15 12:23:00","contentUpdateDate":"2007-04-20 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id15","title":"Results of demonstration trials available","displayCode":"\/Results of demonstration trials available","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3131985","legalName":"SWISS FEDERAL INSTITUTE OF TECHNOLOGY LAUSANNE","address":{"street":"EPFL - Ecublens","city":"LAUSANNE","postalCode":"1015","country":"CH"},"relations":{"regions":[{"name":"Switzerland","rcn":"205949480","nutsCode":"CH","euCode":"CH","isoCode":"CH","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"43902","id":"EVK1-CT-2002-00122_43902_DELIV","title":"Designing and constructing CPCs for solar photocatalytic applications","teaser":"Solar collectors are the key component in any solar installation. After the identification of constructive, structural, mechanical and optical problems of different non-concentrating solar collectors systems, Compound Parabolic Concentrators (CPC) were selected as the best opt...","sourceUpdateDate":"2017-02-15 12:23:00","contentUpdateDate":"2007-04-20 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id15","title":"Results of demonstration trials available","displayCode":"\/Results of demonstration trials available","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3131982","legalName":"AOSOL - ENERGIAS RENOVAVEIS, LDA.","address":{"street":"Parque Industrial de Porto Alto, Lugar de Sesmaria LimpaApartado 173","city":"SAMORA CORREIA","postalCode":"2135-402","country":"PT"},"relations":{"regions":[{"name":"Portugal","rcn":"427199016","nutsCode":"PT","euCode":"PT","isoCode":"PT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"43905","id":"EVK1-CT-2002-00122_43905_DELIV","title":"Detailed engineering of wastewater treatment plants coupling ozone and biotreatment","teaser":"In order the well design the capacity of the ozone production needed in the final ozone plant, the main parameter to take in consideration was not the ratio g O3\/g COT reduced, but the ozone dosage versus the COT reduction.\n\nIn such approach, we may consider with the effluent ...","sourceUpdateDate":"2017-02-15 12:23:01","contentUpdateDate":"2007-04-20 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"84378","title":"Ozone and biotreatment technology for wastewater","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"env","title":"Climate Change and Environment","displayCode":"\/Climate Change and Environment","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"en","rcn":"3131990","legalName":"TRAILIGAZ CIE GENERALE DE L\u0027OZONE SA","address":{"street":"Boulevard de la Muette 29-31","city":"GARGES-LES-GONESSE","postalCode":"95140","country":"FR"},"relations":{"regions":[{"name":"France","rcn":"258902568","nutsCode":"FR","euCode":"FR","isoCode":"FR","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id14","title":"Prototype\/demonstrator available for testing","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"43934","id":"EVK1-CT-2002-00122_43934_DELIV","title":"Design and Control of solar photocatalytic wastewater treatment plants","teaser":"The inability of conventional biological wastewater treatments to effectively remove many toxic pollutants shows that new treatment systems are needed. Rigorous pollution control and legislation in many countries has resulted in an intensive search for new and more efficient w...","sourceUpdateDate":"2017-02-15 12:23:15","contentUpdateDate":"2007-04-20 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id15","title":"Results of demonstration trials available","displayCode":"\/Results of demonstration trials available","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3132126","legalName":"ECOSYSTEM ENVIRONMENTAL SERVICES SA","address":{"street":"Travesia Turo d\u0027en Llull, 12","city":"SANT ANDREU DE LLAVANERES","postalCode":"08392","country":"ES","url":"http:\/\/www.solardetox.net"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"201fb887ebfd18e22fa29966b892abba","archivedDate":"2021-11-16 00:00:00","physUrl":"http:\/\/www.psa.es\/webeng\/projects\/cadox\/index.html","status":"invalid","contenttype":"webLink","attributes":{"represents":"project","source":"corda","type":"relatedWebsite","order":"1"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/429\/97581411\/1181","title":"recycling","displayCode":"\/engineering and technology\/environmental engineering\/waste management\/waste treatment processes\/recycling","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/89023697\/1183","title":"wastewater treatment processes","displayCode":"\/engineering and technology\/environmental engineering\/water treatment processes\/wastewater treatment processes","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/53\/69669548\/1665","title":"photocatalysis","displayCode":"\/natural sciences\/chemical sciences\/catalysis\/photocatalysis","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/45\/277\/829","title":"pollution","displayCode":"\/natural sciences\/earth and related environmental sciences\/environmental sciences\/pollution","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}