The first ultra-high sensitive breast imaging device based on non-ionizing safe microwave

Ziel

Breast cancer is the most common cancer in females. Regular screening is of paramount important for early diagnosis to reduce the incidence and increase the outcome of a cure. Current techniques based on ionizing radiation cannot be used in many cases. MammoWave is a mammography device based on safe microwave that enable a fast and accurate breast
imaging allowing for an early detection of breast cancer, based on simple technology and low cost.
MammoWave can be used any time, at any age and in any condition (pregnancy, specific illness etc.) for all patients since it does not use ionizing radiation. Defer to traditional mammography only cases positive for a first screening MammoWave, limiting the use of harmful radiation.
The breast scanner consist of a cup that hold the breast of the patient in a prone position and of two antennas, one to transmit the microwave signal and one to receive. The breast is exposed to completely safe wave field.
Both antennas are configured to be moved around the azimuth, to capture reflected electromagnetic field in all directions and measured by the
receiving antenna. MammoWave is based on an innovative image reconstruction algorithm that processes the microwave signals according to the Huygens' principle: the result is able to identify the presence of any suspected tumor in the breast tissue.
MammoWave addresses the market of hospitals, clinics and private doctors replying to their need of enhancing the specificity of mammography screening in breast cancer detection to battle the increasing rate of false-positive and false-negative results, which implies additional cost for the healthcare system and unnecessary distress for women.
The Phase 1 project will be focused on establishing a complete supply chain, a sound business model and commercialization strategy, a planning of all activities for performing the clinical trials in hospital departments, as well as the elaboration of an industrialization and marketing plan

Aufforderung zur Vorschlagseinreichung

H2020-SMEInst-2016-2017

Andere Projekte für diesen Aufruf anzeigen

Unterauftrag

H2020-SMEINST-1-2016-2017

Koordinator

UMBRIA BIOENGINEERING TECNOLOGIES SOCIETA A RESPONSABILITA LIMITATA
Netto-EU-Beitrag
€ 50 000,00
Adresse
VIA SANTA MARIA DELLA SPINA 25
06081 Frazione Rivotorto
Italien

Auf der Karte ansehen

KMU

Die Organisation definierte sich zum Zeitpunkt der Unterzeichnung der Finanzhilfevereinbarung selbst als KMU (Kleine und mittlere Unternehmen).

Ja
Region
Centro (IT) Umbria Perugia
Aktivitätstyp
Private for-profit entities (excluding Higher or Secondary Education Establishments)
Links
Gesamtkosten
€ 71 429,00